What Are The Advantages And Disadvantages Of One-piece And Split-type Desuperheater And Pressure Reducer?

Sep 17, 2021

Leave a message

1. Temperature reduction and pressure reducer device, which reduces high temperature and high-pressure steam to low pressure and low-temperature steam that customers can use. According to whether the temperature reduction and pressure reduction are integrated, it can be divided into the following two categories


(1) Integrated temperature reducing and pressure reducing device, temperature reduction, and pressure reduction is carried out in the same temperature reduction and pressure reduction valve


(2) Split type temperature and pressure reducer, temperature reduction, and pressure reduction are carried out separately, and pressure reduction adopts a separate pressure reducing valve


2. What are the advantages and disadvantages of the integrated type and split type of the temperature and pressure reducer are introduced as follows:


(1) The main structure of the integrated temperature and pressure reducer is a steam temperature and pressure reducing valve + a water supply regulating valve + a safety protection device. The steam temperature and pressure reduction are completed in the same valve, and the length of the structure is shorter than that of the split type. , The length of the whole set of equipment is greatly shortened, the floor space is reduced, and the project investment is reduced.


It is applicable to the parameters above the primary steam pressure temperature of 2.5MPa/400℃. Under such steam pressure and temperature conditions, the steam flow rate is also higher. At this time, the use effect of the temperature-reducing valve is better, and the adjustable ratio is 30~100 %.


The adjustment accuracy is high and the versatility is strong. It not only reduces the leakage of the valve, but can reasonably distribute the pressure difference on the water system, but when the primary steam temperature is above 425℃, the outlet steam pipeline can directly use 20 steel (carbon steel) Unlike the split structure, because the primary temperature is not reduced, alloy steel is used for the steam pipe, which increases the cost.


When the primary steam pressure temperature is below 2.5MPa/400℃, the corresponding steam flow rate is also low. At this time, the temperature and pressure reduction effect is not as ideal as the split type. Therefore, when the primary steam pressure temperature is above 2.5MPa/400℃, it is mainly recommended Use an integrated temperature and pressure reduction device.

                                    

(2) The main structure of the split type temperature and pressure reducer is steam pressure reducing valve (regulating valve) + water supply regulating valve + safety protection device, with an adjustable ratio of 30~100% (when equipped with adjustable nozzles, the device can be adjusted The ratio is 10~100%), the steam pressure reducing valve (regulating valve) usually has a sleeve structure, and the leakage is level IV (*higher can reach level V), which is suitable for temperature reduction and pressure reduction of any parameter, but when the temperature of the first steam When the temperature is above 425°C, the secondary steam mixing pipeline needs to use alloy steel, and the cost of the whole set is higher than that of the integrated type, and the length is longer than that of the integrated type.


 The main feature of the split type desuperheating pressure reducer is that the decompression system and the desuperheating system are separated. It is mainly used for harsh working conditions, such as high temperature and high pressure (≤10Mpa, T1≤540℃), to prevent the desuperheating water from scouring the valve body parts, or used for The working condition where the superheated steam with lower pressure is reduced to saturated steam (such as central heating P≤1.8Mpa, T≤280℃) mainly considers the low steam flow rate. Venturi desuperheating is used to fully atomize the desuperheated water to achieve a Better cooling effect.


Send Inquiry