The simplest method of checking a check valve is generally divided into three steps:

Open the check valve path, fill the valve chamber with water (or kerosene), and increase the pressure to the required strength test pressure, check the valve body, bonnet, gasket, packing for leakage.

Close the dead valve path, pressurize one side of the check valve to nominal pressure and check for leakage from the other side.

Turn check valve upside down and test opposite side. Through the above simple three steps can analyze the basic working state of the check valve is abnormal.


Of course, there are also more complex test methods. The methods pointed out below are aimed at more complex potential problems, and the steps can be basically divided into two steps:

Check valve test pressure nominal pressure from 0.4Mpa-32Mpa, these commonly used pressure valves, valve strength test pressure for its nominal pressure 1.5 times. Valve seal test pressure, equal to 1.1 times the nominal pressure.

The check valve test stand usually has a pressing component above and a line below which is connected to the pressure test pump. After the valve is pressed, the pressure test pump works. From the pressure gauge of the pressure test pump, the number of pressure borne by the valve can be read out. Electric valve pressure test when filling water, to the valve air exhaust. The upper pressure plate of the test bed has an exhaust hole and is opened and closed with a small valve. The sign of clean air is that all that comes out of the vent is water. After the vent is closed, the pressure is increased. The pressure boost process should be slow, not sharp. After reaching the specified pressure, keep it for 3 minutes, the pressure does not become qualified.