BRIEF DESCRIPTIONS
The W-601 Desuperheater In Boiler is based on the principle of W-501 of multiple nozzle design. By their design with up to a number of individual nozzles which are fixed around the venturi pipe and connected with a ring line, the water spraying is coming from every direction, particularly suitable for the injection of large amounts of water. The injection of water is controlled via a separate valve and the spring load of the individual nozzles. With a numbers of nozzles structure, this W-601 Desuperheater In Boiler can be applicable for large flow rate steam conditions, also fit for high temperature reduction situations.
DESUPERHEATING PART
Basic Control | |
![]() | |
Main Parts | |
![]() | Venturi Concept The outstanding performance is achieved by unique spring-loaded nozzle design, which provides excellent atomization over a wide range of spray flows. The multi nozzle design optimizes the cooling liquid particle size so that quick evaporation can take place. By utilizing different springs in each nozzle, a better control at low flows can be achieved and the turndown of the liquid control valve can be reduced. |
![]() | Multiple-Nozzle Design As soon as the pressure differential between the water & steam exceeds the set pressure, the plug lifts from its seat and the spray water exits through the small circumferential opening, in the form of a fine mist. Number of nozzles, spring range and spring set pressure is selected based on the process specifications. The spray water quantity is controlled by an external control valve which responds to feedback from a controller and downstream temperature sensor. |
Feed Water Control Valve The feed water control valves' requirement for the desuperheater is critical. The pressure drop across the valve should be minimized, but still give a good control characteristic, sometimes, however, is used for low flows but with high pressure. According to different working conditions and construction investment, we give full types that covers multi-stage type, cage guide type and labyrinth type and more. | |
![]() | High Performance Labyrinth Control Valve The labyrinth control valve is believed to be the best solution for the high pressure drop condition. The essential part of trim is assembled with a number of labyrinth disc, and the path on each disc is designed independently and uniquely, which regulates the velocity of water flow so as to reduce the cavitation, noise and vibration effectively. The specially design of labyrinth trim gives a perfect adjusting accuracy and is available for various flow characteristics of linear and equal-percentage, which is applicable for most conditions. (Details please find control valve brochure) |
Layout Photo | |
![]() | |
SIZE AND DIMENSION
DRAWING | |
![]() | ![]() |
No | Type Code | (Dw×S) DSH Pipe | L | H | L1 | Weight (KG) |
1 | W601-001MX | Φ89×4.5 | 3100 | 205 | 120 | 166 |
2 | W601-002MX | Φ108×4.5 | 3100 | 215 | 120 | 187 |
3 | W601-003MX | Φ133×6 | 3100 | 225 | 120 | 205 |
4 | W601-004MX | Φ159×7 | 3100 | 381 | 200 | 289 |
5 | W601-005MX | Φ219×9 | 3100 | 411 | 200 | 337 |
6 | W601-006MX | Φ273×11 | 3100 | 438 | 200 | 431 |
7 | W601-007MX | Φ325×8 | 3400 | 464 | 200 | 441 |
8 | W601-008MX | Φ377×10 | 3600 | 490 | 225 | 576 |
9 | W601-009MX | Φ426×11 | 3900 | 514 | 245 | 710 |
10 | W601-010MX | Φ530×12 | 3900 | 566 | 450 | 985 |
11 | W601-011MX | Φ630×12 | 4500 | 620 | 500 | 1308 |
12 | W601-012MX | Φ720×12 | 4500 | 661 | 500 | 1524 |
13 | W601-013MX | Φ820×12 | 4500 | 711 | 550 | 2081 |
Hot Tags: desuperheater in boiler, China, suppliers, manufacturers, factory, custom, price, cheap, for sale, hvac desuperheater, pharmaceutical industry desuperheater, adjustable desuperheater, refurbished desuperheater, pressure regulation standard for desuperheater, desuperheater distributor