Heater Safety Valve

Heater Safety Valve
Product Introduction:
Heater safety valve HFA49Y Series is a full nozzle reaction type safety valve designed for low and medium set pressure saturated steam applications.
Send Inquiry
Description
Technical Parameters

BRIEF DESCRIPTIONS

Heater Safety Valve of HFA49Y Series is a full nozzle reaction type safety valve designed for low and medium set pressure saturated steam applications. Its set pressure range is <5.0 MPa, maximal working temperature <350 DegreeC, suitable for most power plant LP steam line service.

Heater Safety Valve has the advantages of disassembly and portability, high precision, high output flow, and accurate pressure design. Its aluminum alloy body ensures high strength and pressure resistance performance.


file0001

DESIGN

Types: Conventional safety valve
Full nozzle with open bonnet, with lever
Available sizes: DN25(1") up to DN200(8")
Available rating: PN16 up to PN50, Class 150# &ndash; 300#
Design Standard: API-526
Medium: Steam under 350 DegreeC
Blowdown: 7%~10%
Discharge Coefficient: G-0.75
Connection Flange: ASME B16.5, GOST-12820, JIS Std

FEATURES

The solid nozzle screws into the body brings easy and convenient maintenance.
The construction of disc and holder is improved to enhance the effect of opening action and gives instant lifting.
The carefully selection material and clearance between disc holder and guide ensures the successful of lifting.
Blowdown control is adjustable by nozzle ring.
The surface of both disc and nozzle seat is deposited with hard alloy of Stellite, and the excellent surface treatment by precision machining and lapping ensure the tightness under high temperature working service


DIMENSION AND SIZE

Type

Nominal Size,Flange,Pressure Grade, Connecting End Face

Structure Size

Weight

HFA48Y-150Lb

NPS

DN

Flange Std

Inlet Flange

Outlet Flange

L

L1

H

Kg

3L4

80

ASME
ANSI/
B16.5

Class150 NPS3 RF

Class150 NPS4 RF

165

155.5

470

44

4M6

100

Class150 NPS4 RF

Class150 NPS6 RF

184

178

576

81.4

4N6

100

Class150 NPS4 RF

Class150 NPS6 RF

210

197

630

89.5

4P6

100

Class150 NPS4 RF

Class150 NPS6 RF

229

181

718

112.5

6Q8

150

Class150 NPS6 RF

Class150 NPS8 RF

241

240

810

157.4

6R8

150

Class150 NPS6 RF

Class150 NPS8 RF

241

240

810

176

8T10

200

Class150 NPS8 RF

Class150 NPS10 RF

279

276

1207

350


Type

Nominal Size,Flange,Pressure Grade, Connecting End Face

Structure Size

Weight

HFA48Y-300Lb

NPS

DN

Flange Std

Inlet Flange

Outlet Flange

L

L1

H

Kg

3L4

80

ASME
ANSI/
B16.5

Class300 NPS3 RF

Class150 NPS4 RF

165

155.5

552

64.5

4M6

100

Class300 NPS4 RF

Class150 NPS6 RF

184

178

576

87

4N6

100

Class300 NPS4 RF

Class150 NPS6 RF

210

197

630

96.5

4P6

100

Class300 NPS4 RF

Class150 NPS6 RF

254

206

790

122.5

6Q8

150

Class300 NPS6 RF

Class150 NPS8 RF

241

240

810

161.1

6R8

150

Class300 NPS6 RF

Class150 NPS8 RF

241

240

1080

286

8T10

200

Class300 NPS8 RF

Class150 NPS10 RF

279

276

1207

388


DEFINITIONS AND TERMINOLOGY

● ACCUMULATION

Pressure increased over the maximum allowable working pressure of the vessel during discharge through the pressure-relief valve (expressed as a percent of that pressure) is called accumulation.

● DESIGN PRESSURE

The pressure used or designated in the design of equipment for the purpose of determining the minimum permissible thickness of the pressure parts at a designated temperature, exclusive of any thickness allowances added for corrosion and for loadings other than pressure.

● BLOW DOWN

Difference between set pressure and reseating pressure of a safety valve are expressed in percent of the set pressure or in bar or kPa.

● MAXIMUM ALLOWABLE WORKING PRESSURE

The maximum gauge pressure permissible at the top of a completed vessel in its operating position for designated temperature. The vessel may not be operated above this pressure or its equivalent at any metal temperature other than that used in its design. Consequently, for that metal temperature, it is the highest pressure at which the primary pressure-relief valve is set to open.

● OVERPRESSURE

Pressure increase over the set pressure of the relieving device is overpressure. It is the same as accumulation when the relieving device is set at the maximum allowable working pressure of the vessel and may be greater than the allowable accumulation if the valve is set lower than the vessel MAWP.

● LIFT

The actual travel of the disc from the closed position when a valve is relieving.

● SET PRESSURE

Inlet pressure to which a safety valve is adjusted, in a test stand or other source of pressure, to open with an atmospheric discharge or atmospheric back pressure.

● RESEATING PRESSURE

The values of inlet static pressure at which the disc re-establishes contact with the seat or at which lift becomes zero.

● BACK PRESSURE

Pressure on the discharge side of safety-relief valves is back pressure.

● BUILT-UP BACK PRESSURE

Built-up back pressure is the pressure in the discharge header which develops as a result of flow after that the safety-relief valve opens.

● SIPERIMPOSED BACK PRESSURE

Superimposed back pressure is the pressure in the discharge header before the safety-relief valve opens.


 

Hot Tags: heater safety valve, China, suppliers, manufacturers, factory, custom, price, cheap, for sale, valve affiliate marketing safety valve, valve referral marketing safety valve